Series 25 Double/Single Hung (Tilting Sash); Canadian Egress Qualification for Standard Sizes

October, 2015

Call Out #

16

20

24

26

28

30

32

36

40

Unit Width

Inches

21 13/16

25 13/16

29 13/16

31 13/16

33 13/16

35 13/16

37 13/16

41 13/16

45 13/16

mm

554

656

758

808

859

910

961

1062

1164

Clear Op

18 1/8"

22 1/8"

26 1/8"

28 1/8"

30 1/8"

32 1/8"

34 1/8"

38 1/8"

42 1/8"

12

Unit Height

32 5/16

821

9 1/8"

1.15

1.40

1.66

1.79

1.91

2.03

2.16

2.42

2.67

14

36 1/4

921

11 1/16"

1.39

1.70

2.01

2.16

2.31

2.46

2.63

2.93

3.24

16

40 1/4

1022

13"

1.64

2.00

2.37

2.54

2.72

2.91

3.09

3.44

3.81

20

48 1/4

1226

17 1/16"

2.14

2.62

3.09

3.33

3.56

3.80

4.04

4.51

4.98

22

52 5/16

1329

19 1/8"

2.41

2.94

3.48

3.74

4.00

4.27

4.53

5.06

5.60

24

56 1/4

1429

21 1/16"

2.65

3.24

3.82

4.11

4.40

4.70

4.99

5.58

6.16

26

60 1/4

1530

24"

3.02

3.69

4.36

4.68

5.03

5.36

5.70

6.35

7.03

28

64 1/4

1632

25 1/16"

3.15

3.84

4.54

4.89

5.23

5.59

5.93

6.63

7.32

30

68 1/4

1734

27 1/16"

3.40

4.15

4.91

5.27

5.66

6.04

6.42

7.16

7.91

32

72 5/16

1837

29 1/4"

3.66

4.48

5.29

5.68

6.09

6.50

6.91

7.71

8.53

34

76 1/4

1937

31 1/16"

3.90

4.77

5.64

6.06

6.50

6.93

7.36

8.22

9.08

36

80 1/4

2038

33"

4.15

5.07

6.00

6.45

6.91

7.37

7.83

8.74

9.67

38

84 1/4

2140

35 1/16"

4.40

5.38

6.36

6.84

7.33

7.81

8.31

9.27

9.80

  • Meets Canadian Egress Requirements

  • Does not meet Canadian Egress Requirements

Notes:

  • Egress requirements referenced in this chart are a minimum clear opening of 15" in width, 15" in height with a minimum opening of 3.8 ft2

  • As local egress codes may vary, it is up to the specifier to determine compliance with local authorities.

  • The information on this chart is subject to change without notice.




Series 25 Double/Single Hung (Tilting Sash); US Egress Qualification for Standard Sizes

October, 2015

Call Out #

16

20

24

26

28

30

32

36

40

Unit Width

Inches

21 13/16

25 13/16

29 13/16

31 13/16

33 13/16

35 13/16

37 13/16

41 13/16

45 13/16

mm

554

656

758

808

859

910

961

1062

1164

Clear Op

18 1/8"

22 1/8"

26 1/8"

28 1/8"

30 1/8"

32 1/8"

34 1/8"

38 1/8"

42 1/8"

12

Unit Height

32 5/16

821

9 1/8"

1.15

1.40

1.66

1.79

1.91

2.03

2.16

2.42

2.67

14

36 1/4

921

11 1/16"

1.39

1.70

2.01

2.16

2.31

2.46

2.63

2.93

3.24

16

40 1/4

1022

13"

1.64

2.00

2.37

2.54

2.72

2.91

3.09

3.44

3.81

20

48 1/4

1226

17 1/16"

2.14

2.62

3.09

3.33

3.56

3.80

4.04

4.51

4.98

22

52 5/16

1329

19 1/8"

2.41

2.94

3.48

3.74

4.00

4.27

4.53

5.06

5.60

24

56 1/4

1429

21 1/16"

2.65

3.24

3.82

4.11

4.40

4.70

4.99

5.58

6.16

26

60 1/4

1530

24"

3.02

3.69

4.36

4.68

5.03

5.36

5.70

6.35

7.03

28

64 1/4

1632

25 1/16"

3.15

3.84

4.54

4.89

5.23

5.59

5.93

6.63

7.32

30

68 1/4

1734

27 1/16"

3.40

4.15

4.91

5.27

5.66

6.04

6.42

7.16

7.91

32

72 5/16

1837

29 1/8"

3.66

4.48

5.29

5.68

6.09

6.50

6.91

7.71

8.53

34

76 1/4

1937

31 1/16"

3.90

4.77

5.64

6.06

6.50

6.93

7.36

8.22

9.08

36

80 1/4

2038

33"

4.15

5.07

6.00

6.45

6.91

7.37

7.83

8.74

9.67

38

84 1/4

2140

35 1/16"

4.40

5.38

6.36

6.84

7.33

7.81

8.31

9.27

9.80

  • Meets US Egress Requirements

  • Does not meet US Egress Requirements

Notes:

  • Egress requirements referenced in this chart are a minimum clear opening of 20" in width, 24" in height with a minimum opening of 5.7 ft2.

  • As local egress codes may vary, it is up to the specifier to determine compliance with local authorities.

  • The information on this chart is subject to change without notice.